APPROVED DOCUMENTS 2010 – F, J, L
With October 2010 came many changes in the Building Regulations for England and Wales. These changes are aimed at reducing the carbon footprint and paving the way to zero-carbon buildings in the UK. Although this brings many new difficult tasks to designers and builders, it is essential for the preservation of our world. The purpose of this post is to point out the key changes to the regulations, and to provide some manufacturers and products suitable for the new regulations.
Among the changes in October were six new Approved Documents:
- AD F 2010 – Ventilation
- AD J 2010 – Combustion appliances and fuel storage systems
- AD L1A 2010 – Conservation of fuel and power: New Dwellings
- AD L1B 2010 – Conservation of fuel and power: Existing Dwellings
- AD L2A 2010 – Conservation of fuel and power: New Buildings other than Dwellings
- AD L2B 2010 – Conservation of fuel and power: Existing Buildings other than Dwellings
As well as three new compliance guides:
- The Domestic Building Services Compliance Guide 2010
- The Non-Domestic Building Services Compliance Guide 2010
- The Domestic Ventilation Compliance Guide 2010
PART J:
SUMMARY:
Part J covers combustion appliances and fuel storage systems. There are many health and safety concerns that drive this document due to the hazardous nature of the appliances it deals with.
The most significant change comes with the new regulation J2A which requires the installation of a carbon monoxide detector in rooms with a new or replaced solid fuel heating appliance. The detector should comply with BS EN 50291:2001 standards. Alarms should be placed 1-3m horizontally away from the appliance, preferably on the ceiling, and at least 300mm away from any wall. If the detector is not placed on the ceiling, then it should be as high as possible on the wall, but not within 150mm of the ceiling. If the detector is battery powered it must have a lifetime battery and be fitted with a warning device to alert users when the battery needs changing. Alarms can also be main powered by fixed wiring, no plug in, and must contain a sensor failure warning device. J2A applies to all solid fuel appliances whether or not the room is sealed.
New requirements have been added for “boxed-in” flues to provide for easy visual inspection. Concealed flues should be provided with visual access to ensure the flue is continuous in length, correctly assembled and sealed at joints, and installed with adequate support, correct gradients and drain points. Horizontal flues should contain at least one access hatch. Access hatches should be a minimum of 300mm x 300mm and be provided at each bend or joint at a 1.5m maximum from each joint.
There has been an increase in permanent ventilation requirements for open flued appliances in homes that have an air permeability of ≤5.0m3/h/m2 @ 50 Pa. Air supply for solid fuel appliances with a flue draught stabiliser now start at 850mm2/kW, and appliances without a stabiliser start at 550mm2/kW. Air supply for gas appliances now start at 500mm2/kW and 550mm2/kW input for oil burning appliances. Buildings built since 2008 should have documented air permeability tests, and older buildings’ air permeability can be assessed using the new Appendix F.
Flue placement and clearance with regards to adjacent or adjoining buildings with pitched roofs has been clarified. A flue serving a solid fuel appliance that passes through the weather surface within 2300mm of an adjacent or adjoining building must be at least 600mm above any part of the building within 2300mm. The new Appendix G gives supplementary information issued in 2004 for chimney designations.
Hearth requirements have slightly changed. While the initial clearances remain unchanged, the document now allows for clearances to be reduced to manufacturers’ recommendations for solid fuel appliances. This is provided they do not exceed a surface temperature of 85°C, and that there is no potential of fuel or ash spillage.
Risk of oil pollution provisions have not changed, but a new provision has been added. Installations located within Zone 1 (inner protection zone) of an Environment Agency Groundwater Source Protection Zone (SPZ) must now have secondary containment. A map of the SPZ can be obtained here.
KEY CHANGES:
- A carbon monoxide detector is required where a new or replaced solid fuel appliance is installed.
- Concealed flues need access for visual inspection, access hatches must be minimum of 300mm x 300mm.
- Air supply to open flued appliances has now changed for buildings with air permeability rates of ≤5.0m3/h/m2.
- Flue placement and clearance with regards to adjacent pitched roofs has been clarified.
- Manufacturer’s recommendations for the size of hearths may be followed for appliances with surface temperatures not exceeding 85°C and where there is no risk of spillage of fuel or ash.
- Now a risk of oil pollution where a storage tank is located within zone 1 of an SPZ.
SPECIFICATION SOLUTIONS:
A carbon monoxide detector is now required where any fixed solid fuel appliance is installed as a new or replacement in a dwelling. This applies to all solid fuel appliances with a rated output of up to 50kW including open fires, solid fuel room heaters, log burners, pellet stoves, and boilers, whether or not the room is sealed.
The flue size should not be smaller than the size of the stove outlet. The minimum flue size for stoves are 125mm diameter for a stove up to 20kW burning smokeless fuel and 150mm diameter for a stove up to 30kW burning any fuel. If a stove is DEFRA (Department for Environment, Food and Rural Affairs) exempt, meaning it has passed tests to confirm that it can burn unauthorised fuels without emitting smoke, then a 125mm diameter flue may be fitted. All other solid fuel appliances should have a minimum flue size of 150mm in diameter as recommended by the regulations.
Rigid twin-walled insulated metal flue liners in top and bottom ventilated masonry chimneys are recommended.
Concealed flues need access hatches to provide for easy visual inspection. Access hatches must be at least 300mm x 300mm in size and should be at every bend or joint of the flue.
Hearths are now allowed clearances to be reduced to manufacturers’ recommendations for solid fuel appliances as long as the surface temperature does not exceed 85°C and that there is no potential of fuel or ash spillage.
Remember, all new boilers must be condensing type.